MEAN WELL  |  SKU: PSU-S605XXXX-01

MEAN WELL S-60-5 Switching Power Supply Output 5Volts, 12Amps

$120.00

Documents

No files available.

MEAN WELL S-60-5

Features

- Universal AC input/ Full range .

- Protections: Short circuit / Overload / Over voltage

- Cooling by free air convection

- 100% full load burn-in test

- Fixed switching frequency at 77KHz

3 year manufacturer warranty

 Specifications

Output

-DC voltage :  5V

-Rated current : 12V

-Current range:  0 ~ 12A

-Rated power : 60W

-Ripple and noise (max.) Note.2 :  120mVp-p

-Voltage Adj. Range : 4.75 ~ 5.5V

-Voltage Tolerance Note.3:  ± 2.0%

-Line regulation : ±0.5%

-Load regulation:  ±1.0%

-Setup, Rise Time : 300ms, 50ms/230VAC 800ms, 50ms/115VAC at full load

-Hold up Time (Typ.) : 80ms/230VAC 12ms/115VAC at full load

Input

-Voltage range (Note 5.) : 85 ~ 264VAC 120 ~ 370VDC

-Frequency range : 47 ~ 63Hz

-Efficiency(Typ.) : 73%

-Ac current (Typ.) : 2A/115VAC 1A/230VAC

- Inrush Current (Typ.): COLD START 20A/115VAC 40A/230VAC

-Leakage Current : <3.5mA / 240VAC

Protection

Overload: 105 ~ 150% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed.

Over voltage : 5.75 ~ 6.75V

Protection type : Hiccup mode, recovers automatically after fault condition is removed.

Environment 

Working Temp. : -10 ~ +60 (Refer to output load derating curve)

working humidity:  20 ~ 90% RH non-condensing

Storage Temp., Humidity:  -20 ~ +85 , 10 ~ 95% RH

Temp. Coefficient  : ± 0.03%/ (0 ~ 50 )

vibration :  10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

Safety and EMC (note 4 )

Safety Standards :  UL1012, UL60950-1, TUV EN60950-1 approved  

Withstand voltage :  I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

Isolation resistance : I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC

EMI conduction and radiation: Compliance to EN55022 (CISPR22) Class B

Harmonic Current : Compliance to EN61000-3-2,-3 

EMS immunity : Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A

Others 

MTBF : 316.2K hrs min. MIL-HDBK-217F (25 )

Dimension : 159*97*38mm (L*W*H)

packing : 0.51Kg; 24pcs/13.1Kg/0.7CUFT

Note 

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives

  • US Stock

    One day shipping or store pick up

  • Reliability

    Reliable A/V part checked by AzarPixel

  • Easy Returns

    No question 30 days return

  • Tech Support

    Free technical assistance

MEAN WELL S-60-5 Switching Power Supply Output 5Volts, 12Amps
MEAN WELL

MEAN WELL S-60-5 Switching Power Supply Output 5Volts, 12Amps

$120.00

MEAN WELL S-60-5

Features

- Universal AC input/ Full range .

- Protections: Short circuit / Overload / Over voltage

- Cooling by free air convection

- 100% full load burn-in test

- Fixed switching frequency at 77KHz

3 year manufacturer warranty

 Specifications

Output

-DC voltage :  5V

-Rated current : 12V

-Current range:  0 ~ 12A

-Rated power : 60W

-Ripple and noise (max.) Note.2 :  120mVp-p

-Voltage Adj. Range : 4.75 ~ 5.5V

-Voltage Tolerance Note.3:  ± 2.0%

-Line regulation : ±0.5%

-Load regulation:  ±1.0%

-Setup, Rise Time : 300ms, 50ms/230VAC 800ms, 50ms/115VAC at full load

-Hold up Time (Typ.) : 80ms/230VAC 12ms/115VAC at full load

Input

-Voltage range (Note 5.) : 85 ~ 264VAC 120 ~ 370VDC

-Frequency range : 47 ~ 63Hz

-Efficiency(Typ.) : 73%

-Ac current (Typ.) : 2A/115VAC 1A/230VAC

- Inrush Current (Typ.): COLD START 20A/115VAC 40A/230VAC

-Leakage Current : <3.5mA / 240VAC

Protection

Overload: 105 ~ 150% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed.

Over voltage : 5.75 ~ 6.75V

Protection type : Hiccup mode, recovers automatically after fault condition is removed.

Environment 

Working Temp. : -10 ~ +60 (Refer to output load derating curve)

working humidity:  20 ~ 90% RH non-condensing

Storage Temp., Humidity:  -20 ~ +85 , 10 ~ 95% RH

Temp. Coefficient  : ± 0.03%/ (0 ~ 50 )

vibration :  10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

Safety and EMC (note 4 )

Safety Standards :  UL1012, UL60950-1, TUV EN60950-1 approved  

Withstand voltage :  I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

Isolation resistance : I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC

EMI conduction and radiation: Compliance to EN55022 (CISPR22) Class B

Harmonic Current : Compliance to EN61000-3-2,-3 

EMS immunity : Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A

Others 

MTBF : 316.2K hrs min. MIL-HDBK-217F (25 )

Dimension : 159*97*38mm (L*W*H)

packing : 0.51Kg; 24pcs/13.1Kg/0.7CUFT

Note 

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives