Features
- AC input range selectable by switch
- Withstand 300VAC surge input for 5 second
- Protections: short circuit/Overload/Over voltage/Over temperature
- Forced air cooling by built-in DS fan
- Built-in cooling fan ON-OFF control
- 1U low profile
- Withstand 5G vibration test
- LED indicator for power on
- No-load power consumption <0.75 W
- 100% full load burn-in test
- High operating temperature up to 70 Celsius
- Operating altitude up to 5000 meters
- High efficiency, long life, and high reliability
Description
- LRS-350 series is a 350W single-output enclosed type power supply with 30 mm of low-profile design. Adopting the input of 115VAC or 230VAC (select by switch), the entire series provides an output voltage line of 3.3V, 4.2V, 5V, 12V, 15V, 24V, 36V, and 48V. in addition to the high efficiency of up to 89%, with the built-in long-life fan LRS-350 can work under-25 through +70℃ with a full load. Delivering an extremely low no-load power consumption (less than 0.75 w), it allows the end system to easily meet the worldwide energy requirement. LRS-350 has complete protection functions and 5G anti-vibration capability, it has complied with international safety regulations such as IEC/UL 62368 -1. LRS-350 series serves as a high price to performance power supply solution for various industrial applications.
Specifications
OUTPUT
- DC VOLTAGE 5V
- RATED CURRENT 60 A
- CURRENT RANGE 0 ~ 60A
- RATED POWER 300W
- RIPPLE & NOISE (max.) 150mVp-p
- VOLTAGE ADJ. RANGE 4.5 ~ 5.5V
- VOLTAGE TOLERANCE ±3.0%
- LINE REGULATION ±0.5%
- LOAD REGULATION ±2.0%
- SETUP, RISE TIME 1300ms, 50ms/230VAC 1300ms,50ms/115VAC at full load
- HOLD UP TIME (Typ.) 16ms/230VAC 12ms/115VAC at full load
INPUT
- VOLTAGE RANGE 90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (switch on 230VAC)
- FREQUENCY RANGE 47 ~ 63Hz
- EFFICIENCY (Typ.) 83.5%
- AC CURRENT (Typ.) 6.8A/115VAC 3.4A/230VAC
- INRUSH CURRENT (Typ.) COLD START 60A/115VAC 60A/230VAC
- LEAKAGE CURRENT <2mA / 240VAC
PROTECTION
OVERLOAD
- 110 ~ 140% rated output power
- 3.3~36V Hiccup mode recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover.
OVERVOLTAGE
- 5.75 ~ 6.75V
- 3.3~36V Hiccup mode recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover.
OVER-TEMPERATURE
- 3.3~36V Hiccup mode recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover.
ENVIRONMENT
- WORKING TEMP -25 ~ +70℃
- WORKING HUMIDITY 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
- TEMP COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
- VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY
SAFETY STANDARDS
- IEC/UL 62368-1, BSMI CNS14336-1, EAC TP TC 004, KC K60950-1(for LRS-350-12/24 only), BIS IS 13252(Part1): 2010/IEC 60950-1: 2005, AS/NZS62368.1 approved
WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
- Compliance to BSMI CNS13438, EAC TP TC 020, KC KN32, KN35(for LRS-350-12/24 only)
EMC IMMUNITY
- Compliance to EAC TP TC 020,KC KN32,KN35(for LRS-350-12/24 only)
OTHERS
- MTBF 327.9K hrs. min. MIL-HDBK-217F (25℃)
- DIMENSION 215*115*30mm (L*W*H)