MEAN WELL RSP-200-5

Features

-Universal AC input / Full range

-Built-in active PFC function, PF>0.95

-high efficiency up to 90 %

-Protections: Short circuit / Overload / Over voltage / Over temperature

-Cooling by free air convection

-1U low profile 30mm

-Optional conformal coating models (RSP-200- CC)

-LED indicator for power on

Specifications

Output

-DC voltage: 5V 

-Rated current: 40A

-Current range:  0 ~ 40A

-Rated power: 200W

-Ripple and noise (max.) Note.2:  150mVp-p

-Voltage Adj. Range: 4.5 ~ 5.5V

-Voltage Tolerance Note.3:  ± 2.0%

-Line regulation: ± 0.5%

-Load regulation:  ±1.0%

-Setup, Rise Time: 1500ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load

-Hold up Time (Typ.): 8ms at full load 230VAC /115VAC

Input

-Voltage range (Note 4.): 88 ~ 264VAC 124 ~ 370VDC

-Frequency range: 47 ~ 63Hz

-POWER FACTOR (Typ.) : PF>0.95/230VAC PF>0.98/115VAC at full load

-Efficiency (Typ.): 87%

-Ac current (Typ.): 2A/115VAC   1.1A/230VAC

- Inrush Current (Typ.): 20A/115VAC 40A/230VAC

-Leakage Current: <1mA / 240VAC

Protection

Overload: 105 ~ 135% rated output power

Protection type: Hiccup mode, recovers automatically after fault condition is removed.

Over voltage: 5.75 ~ 7 V

Protection type: Shut down o/p voltage, re-power on to recover.

Over temperature: 110 °C ±5 °C (TSW1) detect on heatsink of main power output choke)

Protection type: Shut down o/p voltage, recovers automatically after temperature goes down.

Environment 

Working Temp.: -30 ~ +70 °C (Refer to "Derating Curve")

working humidity:  20 ~ 90% RH non-condensing

Storage Temp., Humidity:  -40 ~ +85 °C, 10 ~ 95% RH

Temp. Coefficient: ±0.03%/°C (0~45 °C)

vibration:  10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

Safety and EMC (note 5 )

Safety Standards:   UL60950-1, TUV EN60950-1 approved.

Withstand voltage:  I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC

Isolation resistance: I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 °C / 70% RH

EMC Emission: Compliance to EN55022 (CISPR22) Class B, EN61000-3-2, -3

EMC Immunity: Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A

Others 

MTBF: 224.5K hrs min. MIL-HDBK-217F (25 °C)

Dimension: 215*115*30mm (L*W*H)

packing: 0.72Kg

3-year manufacturer warranty

Note 

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltages. Please check the derating curve for more details. 

5.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies."

Payment & Security

Payment methods

  • American Express
  • Diners Club
  • Discover
  • Meta Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

MEAN WELL RSP-200-5 Switching power Supply
MEAN WELL

MEAN WELL RSP-200-5 Switching power Supply, Output 5Volts 40Amps

$69.33

MEAN WELL RSP-200-5

Features

-Universal AC input / Full range

-Built-in active PFC function, PF>0.95

-high efficiency up to 90 %

-Protections: Short circuit / Overload / Over voltage / Over temperature

-Cooling by free air convection

-1U low profile 30mm

-Optional conformal coating models (RSP-200- CC)

-LED indicator for power on

Specifications

Output

-DC voltage: 5V 

-Rated current: 40A

-Current range:  0 ~ 40A

-Rated power: 200W

-Ripple and noise (max.) Note.2:  150mVp-p

-Voltage Adj. Range: 4.5 ~ 5.5V

-Voltage Tolerance Note.3:  ± 2.0%

-Line regulation: ± 0.5%

-Load regulation:  ±1.0%

-Setup, Rise Time: 1500ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load

-Hold up Time (Typ.): 8ms at full load 230VAC /115VAC

Input

-Voltage range (Note 4.): 88 ~ 264VAC 124 ~ 370VDC

-Frequency range: 47 ~ 63Hz

-POWER FACTOR (Typ.) : PF>0.95/230VAC PF>0.98/115VAC at full load

-Efficiency (Typ.): 87%

-Ac current (Typ.): 2A/115VAC   1.1A/230VAC

- Inrush Current (Typ.): 20A/115VAC 40A/230VAC

-Leakage Current: <1mA / 240VAC

Protection

Overload: 105 ~ 135% rated output power

Protection type: Hiccup mode, recovers automatically after fault condition is removed.

Over voltage: 5.75 ~ 7 V

Protection type: Shut down o/p voltage, re-power on to recover.

Over temperature: 110 °C ±5 °C (TSW1) detect on heatsink of main power output choke)

Protection type: Shut down o/p voltage, recovers automatically after temperature goes down.

Environment 

Working Temp.: -30 ~ +70 °C (Refer to "Derating Curve")

working humidity:  20 ~ 90% RH non-condensing

Storage Temp., Humidity:  -40 ~ +85 °C, 10 ~ 95% RH

Temp. Coefficient: ±0.03%/°C (0~45 °C)

vibration:  10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

Safety and EMC (note 5 )

Safety Standards:   UL60950-1, TUV EN60950-1 approved.

Withstand voltage:  I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC

Isolation resistance: I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 °C / 70% RH

EMC Emission: Compliance to EN55022 (CISPR22) Class B, EN61000-3-2, -3

EMC Immunity: Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A

Others 

MTBF: 224.5K hrs min. MIL-HDBK-217F (25 °C)

Dimension: 215*115*30mm (L*W*H)

packing: 0.72Kg

3-year manufacturer warranty

Note 

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltages. Please check the derating curve for more details. 

5.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies."