This model belongs to the Dual Output Switching Power Supplies category.

Features:

  • Universal AC input/Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • LED indicator for power on
  • Fixed switching frequency at 54KHz
  • 2 years warranty

Specifications: 

Output : 

- Output number: Ch1/Ch2 

-DC voltage : 5V/12V

-Rated current : 4A/3A

-Current range: 0.3 ~ 6A/ 0.2 ~ 4A

-Rated power : 56W

-Ripple and noise (max.) Note.2 : 6W 75mVp-p/150mVp-p

-Voltage Adj. Range : CH1 : 4.75 ~ 5.5V

-Voltage Tolerance Note.3: ±2.0% / ±6.0%

-Line regulation : ±0.5% / ± 1.0%

-Load regulation:  ±0.5 %  /± 4.0%

-Setup, Rise Time : 300ms, 50ms / 230VAC 800ms, 50ms / 115VAC at full load

-Hold up Time (Typ.) : 80ms/230VAC 10ms/115VAC at full load

Input: 

-Voltage range : 85 ~ 264VAC 120 ~ 370VDC

-Frequency range : 47 ~ 63Hz

-Efficiency(Typ.) : 73% 

-Ac current (Typ.) : 2A/115VAC 1A/230VAC

- Inrush Current (Typ.): COLD START 20A/115VAC 40A/230VAC

-Leakage Current : <3.5mA / 240VAC 

Protection: 

overload :    105 ~ 150% rated output power

                     Protection type : Hiccup mode, recovers automatically after fault condition is removed.

Over voltage :  5V : 5.75 ~ 6.75V

                          Protection type : Hiccup mode, recovers automatically after fault condition is removed.

Environment : 

Working Temp.  -10 ~ +60 (Refer to output load derating curve)

working humidity   20 ~ 90% RH non-condensing

Storage Temp., Humidity 20 ~ +85 , 10 ~ 95% RH

Temp. Coefficient  ± 0.03%/ (0 ~ 50 ) on +5V output

vibration 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

Safety and EMC  (Note 4)

Safety Standards :   UL1012, UL60950-1, TUV EN60950-1 approved

Withstand voltage :  I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

Isolation resistance : I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH

Emi conduction and radiation: Compliance to EN55022 (CISPR22) Class B

Harmonic Current: Compliance to EN61000-3-2,-3

Ems Immunity : Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A

Others 

MTBF 301.2K hrs min. MIL-HDBK-217F (25 )

Dimension 159*97*38mm (L*W*H)

packing  0.54Kg; 24pcs/13.8Kg/0.75CUFT

Note

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4.  The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.

 

You may also like

Recently viewed