MEAN WELL Sp-240-12 Switching Power Supply Output 12Volts, 20Amps
MEAN WELL Sp-240-12 Switching Power Supply Output 12Volts, 20Amps is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Documents
Documents
No files available.
This model belongs to the Single Output with PFC Function.
MEAN WELL Sp-240-12
Features:
-Universal Ac input/ Full range.
- built in fan ON / OFF control
- LED indicator for power on
-fixed switching frequency at 90KHz
3 year manufacturer warranty
Specifications:
Output:
- DC VOLTAGE: 12V
- Rated current: 20A
- Current range: 0~ 20A
- Rated power: 240 W
- Ripple and noise (max.) Note.2: 150mVp-p
- Voltage ADJ. range: 10 ~ 14V
- Voltage tolerance Note.3: ±0%
- Line regulation: ±0.3%
- Load regulation: ±0.5%
- Setup, rise time: 800 ms, 50ms/230VAC 1500ms, 50ms/115VAC at full load
- Hold up time (Typ): 20ms/230VAC 20ms/115VAC at full load
Input:
- voltage range: 88 ~ 264VAC 124 ~ 370VDC
- frequency range: 47 ~ 63Hz
- power factor (typ): pF>0.95/230VAC PF>0.98/115VAC at full load
- efficiency (Typ): 86%
- Ac Current (Typ): 3.6A/115VAC 1.8A/230VAC
- Inrush current (Typ): 25A/115VAC 40A/230VAC
- Leakage current: <2mA / 240VAC
Protection:
- Overload: 105 ~ 135% rated output power
- Over voltage: 4.7 ~ 17.5V
protection type: Shut down o/p voltage, re-power on to recover
- Over temperature: 90 5 (5V,7.5V), 85 5 (12V,15V,24V,30V,48V) (TSW1: detect
on heatsink of power transistor)
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
Function:
- Fun control: RTH2 40 FAN ON, 35 FAN OFF(Typ.)
Environment:
- Working temp: -20 ~ +70 (Refer to output load derating curve)
- Working humidity: 20 ~ 90% RH non-condensing
- Storage Temp, humidity: -0 ~ +85, 10 ~ 95% RH
- Temp coefficient: ±03%/ (0 ~ 50 C)
- Vibration: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Safety and EMC (note 4)
Safety standards: UL60950-1, TUV EN60950-1 approved
- Withstand voltage: I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
- Isolation resistance: /P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
- Emi conduction and radiation: Compliance to EN55022 (CISPR22) Class B
- Harmonic current: Compliance to EN61000-3-2, -3
- EMS immunity: Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
Others:
MTBF: 284K hrs min. MIL-HDBK-217F (25)
DIMENSION: 190*93*50mm (L*W*H)
PACKING: 0.8Kg
Note:
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance: includes set up tolerance, line regulation and load regulation.
- The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
- Derating may be needed under low input voltages. Please check the derating curve for more detail