MEAN WELL T-60-C Switching Power Supply 15Volts, 5Amps
MEAN WELL T-60-C Switching Power Supply 15Volts, 5Amps is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Description
Description
MEAN WELL T-60-C
Features
-Universal AC input / Full range
-Protections: Short circuit / Overload / Over voltage
-Cooling by free air convection
-LED indicator for power on
-Fixed switching frequency at 50KHz
Specifications
Output
-Output number: Ch1/Ch2/Ch3
-DC voltage: 5V/15V/-15V
-Rated current: 5A/2A/0.5A
-Current range: 0.5~7A/ 0.2~3A / 0~1A
-Rated power: 62.5W
-Ripple and noise (max.) Note 2: 100mVp-p/100mVp-p/100mVp-p
-Voltage Adj. Range: CH1: 4.75 ~ 5.5V
-Voltage Tolerance Note.3: ±2.0%/±6.0%/±6.0%
-Line regulation: ± 0.5%/±1.0%/±0.5%
-Load regulation: ±1.0%/±4.0%/±1.0%
-Setup, Rise Time: 300ms, 50ms/230VAC 800ms, 50ms/115VAC at full load
-Hold up Time (Typ.): 80ms/230VAC 10ms/115VAC at full load
Input
-Voltage range: 85 ~ 264VAC / 120~370VDC
-Frequency range: 47 ~ 63Hz
-Efficiency (Typ.): 72%
-Ac current (Typ.): 2A/115VAC 1A/230VAC
- Inrush Current (Typ.): COLD START 20A/115VAC 40A/230VAC
-Leakage Current: <3.5mA / 240VAC
Protection
Overload: 105 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed.
Over voltage : 5V:5.75 ~ 6.75V
Protection type: Hiccup mode, recovers automatically after fault condition is removed.
Environment:
Working Temp: -10 ~ +60 °C (refer to Output load Derating Curve)
working humidity: 20 ~ 90% RH non-condensing
Storage Temp., Humidity: -20~ +85 °C, 10 ~ 95% RH
Temp. Coefficient: ±0.03%/°C (0~50 °C) on +V output
Vibration: 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Safety and EMC (note4)
Safety Standards : UL1012, UL60950-1, TUV EN60950-1 approved
Withstand voltage : I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC
Isolation resistance : I/P-O/P, I/P-FG, O/P-FG:100M Ohms /500VDC / 25℃/ 70% RH
EMI conduction and radiation: Compliance to EN55022 (CISPR22) Class B
Harmonic current : Compliance to EN61000-3-2,-3
EMS immunity : Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
Others
MTBF : 281.1K hrs min. MIL-HDBK-217F (25°C )
Dimension : 159*97*38 mm (L*W*H)
Packing : 0.55Kg
3 year manufacturer warranty
Notes
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to ''EMI testing of component power supplies.''
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.