Gold power  |  SKU: PSU-G201M51B-01

Gold power GPAD201M5-1B Switching Power Supply Output 4.5Volts ,40Amps

$135.36


Description

The Gold Power GPAD201M5-1B Power Supply is an ideal solution for your IT system needs. With an AC input voltage range of 90-264V and a one-way output of 26V, it is designed strictly in accordance with safety regulations and conforms to the safety standards and requirements of information technology.

The power supply is equipped with protections against output over-current, short-circuit, and output over-voltage, ensuring the safety and reliability of your system. The output voltage range is adjustable between 4.2V to 5V, and the output current range is up to 40A, with a regulation of ±1% rated voltage input variation for all loads. The stabilized voltage precision is ±5% for all-voltage input range and all-load output.

The Gold Power GPAD201M5-1B Power Supply features a dynamic response overshoot of ±5%, with a rate of 0.1A/us and cycle of 4ms. It has a temperature coefficient of ±0.02%/℃ in the operating temperature range and a startup output delay of 2 seconds at 220V AC full-load.

The power supply also includes output over-voltage protection at 6-6.5V, output current-limiting protection at 58-70A with over-current hiccup and output 4.5V protection point, and output short-circuit protection, which is long-term short-circuit endurable and auto-recoverable. Over-temperature protection is also included, which turns off the power supply at over-temperature and is auto-recoverable.

The Gold Power GPAD201M5-1B Power Supply meets various EMC and safety standards, including EN55022 – Class A, EN61000-4-5, EN61000-4-2, EN61000-4-3 LEVEL 3, EN61000-4-6 LEVEL 3, IEC61000-4-4, IEC61000-3-2, and has an MTBF of ≥200,000 hours. It also features mechanical characteristics, with dimensions of 220x50x26mm and a weight of ≤1kg.

Ambient Requirements
Parameter Min. Typ. Max. Unit Remark
Operating temperature -25 65 85 °C No condensing
Storage temperature -25 25 100 °C No condensing
Relative humidity 5 95 % No condensing
Altitude 0 4000 m Max temperature will be derated by 1℃,per200m @ altitude of 3000~4000m
Cooling Conductive coolingthe underside of the case shall be close to the heat-sink
Input
Parameter Min. Typ. Max. Unit Remark
AC input voltage range 90 110/220 264 Vac
frequency 47 50/60 63 Hz
Power factor 0.95 220Vac full-load
Inrush current 50 A 220Vacfull-load/cold state
AC input phase Single-phase input LN Support for single-phase
Output
Parameter Min. Typ. Max. Unit Remark
Output voltage range 4.2 4.5 5 Vdc adjustable
Output setting voltage 4.45 4.5 4.55 Vdc
Output current range 0 40 A All-voltage input range
Regulation ±1 % Rated voltage input,variation:all-loads
Stabilized voltageprecision ±5 % All-voltage input range/all-load output
Load regulation ±0.5 % Rated current output;Variation:all-voltage range
Ripple +noise(Vp-p) 200 mV all input voltage and load range,with a 0.1uF film capacitor and 10uF electrolyte capacitor,oscilloscope band width of
Other outputs
Parameter Min. Typ. Max. Unit Remark
Outpu power 200 W
Output efficiency 88 90 % 220Vac input, output all-load,@normal temperature
Dynamic response overshoot ±5 % Load variation:25%-50%-25% or 50%-75%-50% Rate: 0.1A/uscycle:4ms
Dynamic response overshoot ±10 %
Temperature coefficient ±0.02 %/℃ Rated output voltage and output current,all operating temperature range
Startup output delay 2 S 220Vac ,full-load
Startup/turndown overshoot ±10 % All-voltage input range,all-load ouput
Output voltage rise-up time 100 ms Rated input/outpu
Capactive load 4700 10000 uF All voltage,load range
Protection
Parameter Min. Typ. Max. Unit Remark
Output over-voltage protection point 6 6.5 V Output be dead-locked
Output current-limiting protection point 58 70 A Over-current hiccup,output 4.5V
Output short-circuit protection Long-term short-circuit endurable; auto-recoverable
Over-temperature protection 85 95 Turn off @ over-temperature, auto-recoverable. Tested @ the central of the enclosure
EMC and others
Parameter Standard
(CE) EN55022 - Class A
(RE) EN55022 - Class A
SURGE EN61000-4-5 inputlineline 1KVlineground 2KV
ESD EN61000-4-2 contact discharge±4KV, air discharge±8KV 。(criteria B
(RS) EN61000-4-3 LEVEL 3criteria A10V/m field intensiy
(CS) EN61000-4-6 LEVEL 3criteria A10V
EFT/B ±2KVLEVEL 3criteria B IEC61000-4-4
Frequency:1-4Hzacceleration spectral density:0.0001g2/HzFrequency :4-100Hz, acceleration spectral density :0.01g2/HzFrequency :100-200Hzacceleration spectral density :0.001g2/Hz
Vibration 0.781Grmsdirections3duration:30min per direction
Shock Half-sine-waveacceleration300m/s2pulse width6msdirections6times3times per direction
Voltage fluctuation Pst≤1.0 dc≤3%
P1t≤0.65 dmax≤4% duration of d(t)over 3.3%≤200ms
Current harmonics CLASS A IEC61000-3-2 6
Acoustic noise 55dB(A)distance:1m
MTBF MTBF≥200,000h
Odor No preculiar and deleterious odor
Safety & insulation grade
Parameter Standard Remark
Input-output 3000Vac/10mA//1min No flashover or breakdown
Input-ground 1500Vac/10mA//1min No flashover or breakdown
Output-ground 500Vdc/10mA//1min No flashover or breakdown
Insulation resistance 10MΩ Under normal atmosphere,relative humidityis 90%.When testing voltage is DC500V,the resistance of input-output,input-GND,output-GND is not less than 10MΩ.
leakage current 1 mA
Mechanical features
Long*width*height 220*50*26mm
Weight kg ≤1Kg

Payment & Security

Payment methods

  • American Express
  • Diners Club
  • Discover
  • Meta Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Gold power GPAD201M5-1B Switching Power Supply Output 4.5Volts ,40Amps
Gold power

Gold power GPAD201M5-1B Switching Power Supply Output 4.5Volts ,40Amps

$135.36

The Gold Power GPAD201M5-1B Power Supply is an ideal solution for your IT system needs. With an AC input voltage range of 90-264V and a one-way output of 26V, it is designed strictly in accordance with safety regulations and conforms to the safety standards and requirements of information technology.

The power supply is equipped with protections against output over-current, short-circuit, and output over-voltage, ensuring the safety and reliability of your system. The output voltage range is adjustable between 4.2V to 5V, and the output current range is up to 40A, with a regulation of ±1% rated voltage input variation for all loads. The stabilized voltage precision is ±5% for all-voltage input range and all-load output.

The Gold Power GPAD201M5-1B Power Supply features a dynamic response overshoot of ±5%, with a rate of 0.1A/us and cycle of 4ms. It has a temperature coefficient of ±0.02%/℃ in the operating temperature range and a startup output delay of 2 seconds at 220V AC full-load.

The power supply also includes output over-voltage protection at 6-6.5V, output current-limiting protection at 58-70A with over-current hiccup and output 4.5V protection point, and output short-circuit protection, which is long-term short-circuit endurable and auto-recoverable. Over-temperature protection is also included, which turns off the power supply at over-temperature and is auto-recoverable.

The Gold Power GPAD201M5-1B Power Supply meets various EMC and safety standards, including EN55022 – Class A, EN61000-4-5, EN61000-4-2, EN61000-4-3 LEVEL 3, EN61000-4-6 LEVEL 3, IEC61000-4-4, IEC61000-3-2, and has an MTBF of ≥200,000 hours. It also features mechanical characteristics, with dimensions of 220x50x26mm and a weight of ≤1kg.

Ambient Requirements
Parameter Min. Typ. Max. Unit Remark
Operating temperature -25 65 85 °C No condensing
Storage temperature -25 25 100 °C No condensing
Relative humidity 5 95 % No condensing
Altitude 0 4000 m Max temperature will be derated by 1℃,per200m @ altitude of 3000~4000m
Cooling Conductive coolingthe underside of the case shall be close to the heat-sink
Input
Parameter Min. Typ. Max. Unit Remark
AC input voltage range 90 110/220 264 Vac
frequency 47 50/60 63 Hz
Power factor 0.95 220Vac full-load
Inrush current 50 A 220Vacfull-load/cold state
AC input phase Single-phase input LN Support for single-phase
Output
Parameter Min. Typ. Max. Unit Remark
Output voltage range 4.2 4.5 5 Vdc adjustable
Output setting voltage 4.45 4.5 4.55 Vdc
Output current range 0 40 A All-voltage input range
Regulation ±1 % Rated voltage input,variation:all-loads
Stabilized voltageprecision ±5 % All-voltage input range/all-load output
Load regulation ±0.5 % Rated current output;Variation:all-voltage range
Ripple +noise(Vp-p) 200 mV all input voltage and load range,with a 0.1uF film capacitor and 10uF electrolyte capacitor,oscilloscope band width of
Other outputs
Parameter Min. Typ. Max. Unit Remark
Outpu power 200 W
Output efficiency 88 90 % 220Vac input, output all-load,@normal temperature
Dynamic response overshoot ±5 % Load variation:25%-50%-25% or 50%-75%-50% Rate: 0.1A/uscycle:4ms
Dynamic response overshoot ±10 %
Temperature coefficient ±0.02 %/℃ Rated output voltage and output current,all operating temperature range
Startup output delay 2 S 220Vac ,full-load
Startup/turndown overshoot ±10 % All-voltage input range,all-load ouput
Output voltage rise-up time 100 ms Rated input/outpu
Capactive load 4700 10000 uF All voltage,load range
Protection
Parameter Min. Typ. Max. Unit Remark
Output over-voltage protection point 6 6.5 V Output be dead-locked
Output current-limiting protection point 58 70 A Over-current hiccup,output 4.5V
Output short-circuit protection Long-term short-circuit endurable; auto-recoverable
Over-temperature protection 85 95 Turn off @ over-temperature, auto-recoverable. Tested @ the central of the enclosure
EMC and others
Parameter Standard
(CE) EN55022 - Class A
(RE) EN55022 - Class A
SURGE EN61000-4-5 inputlineline 1KVlineground 2KV
ESD EN61000-4-2 contact discharge±4KV, air discharge±8KV 。(criteria B
(RS) EN61000-4-3 LEVEL 3criteria A10V/m field intensiy
(CS) EN61000-4-6 LEVEL 3criteria A10V
EFT/B ±2KVLEVEL 3criteria B IEC61000-4-4
Frequency:1-4Hzacceleration spectral density:0.0001g2/HzFrequency :4-100Hz, acceleration spectral density :0.01g2/HzFrequency :100-200Hzacceleration spectral density :0.001g2/Hz
Vibration 0.781Grmsdirections3duration:30min per direction
Shock Half-sine-waveacceleration300m/s2pulse width6msdirections6times3times per direction
Voltage fluctuation Pst≤1.0 dc≤3%
P1t≤0.65 dmax≤4% duration of d(t)over 3.3%≤200ms
Current harmonics CLASS A IEC61000-3-2 6
Acoustic noise 55dB(A)distance:1m
MTBF MTBF≥200,000h
Odor No preculiar and deleterious odor
Safety & insulation grade
Parameter Standard Remark
Input-output 3000Vac/10mA//1min No flashover or breakdown
Input-ground 1500Vac/10mA//1min No flashover or breakdown
Output-ground 500Vdc/10mA//1min No flashover or breakdown
Insulation resistance 10MΩ Under normal atmosphere,relative humidityis 90%.When testing voltage is DC500V,the resistance of input-output,input-GND,output-GND is not less than 10MΩ.
leakage current 1 mA
Mechanical features
Long*width*height 220*50*26mm
Weight kg ≤1Kg
View product