Get 10% off your first online order with code: WELCOME10

TDK LAMBDA  |  SKU: F8-UNS9-66YT

TDK LAMBDA SWS-100-5 Switching Power Supply Output 5Volts, 20Amps

$197.00


Description

TDK LAMBDA SWS-100-5

Features

-Low Cost

-Power Factor Correction to EN61000-3-2

-Universal Input (85 - 265VAC)

-Input Transient Protected IEC61000-4

-Enclosed

-Global safety Approvals

-Level B EMI

Key market segments and applications:   industrial, comm, Led, test.

Specifications:

  • Input Voltage range (1): 85 - 265VAC (47 - 63Hz) or 120 - 370VDC
  • Inrush Current (115 / 230VAC): 16/32
  • Power Factor: Meets EN61000-3-2
  • Input Current (100/200VAC): 1.2/0.6 
  • Temperature Coefficient: <0.02%/°C  
  • Total regulation: <5%
  • Overcurrent Protection: >105%, Constant Current Style
  • Overvoltage Protection: 115 -135%, Cycle AC line to reset
  • Hold Up Time (Typ): 20ms at 115VAC
  • Leakage Current (max): 0.75mA (0.5mA typ@230VAC)
  • Remote Sense:  Not Available
  • LED Indicator: Green LED = On
  • Operating Temperature:  -10 to +70°C (See table for derating - model specific)
  • Storage Temperature:  -30 to +85°C
  • Operating Humidity: 30 - 90% RH
  • Storage Humidity : 10 - 95% RH
  • Cooling: Convection
  • Withstand Voltage : Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
  • Isolation Resistance: >100M at 25°C & 70%RH, Output to Ground 500VDC
  • Vibration (non-operating): 19.6m/s2 (10 - 55Hz (constant sweep 1 min) X, Y, Z for 1 hour)
  • shock: < 196.1 m/s2 (20G)
  • Safety Agency Approvals:  UL60950-1, CSA60950-1, EN60950-1, CE Mark, EN50178
  • Conducted & Radiated EMI: EN55011 / EN55022-B, FCC Class B, VCCI-B
  • Recommended EMI Filter: RSEL-2002W
  • Immunity :   EN61000-4-2,-3,-4,-5,-6,-8,-11
  • Weight (Typ): 600g
  • Size (WxHxD): 3.78 x 1.77 x 7.4 in

Model selector:

-voltage:              5V

-Adjust range:   4.5-5.5V

-Max Curr. (A):    20

-Load Reg (mv):  40

-Line Reg (mv):   20

-Ripple noise:    100

-Eff (3) (typ) %:   75/77

Derating:

At 25°C: 100 %

At 30°C:  100 %

At 35 °C:  100 %

At 40°C:  100 %

At 45 °C: 100 %

At 50 °C: 87%

At 55 °C: 73 %

At 60 °C: 60 %

Payment & Security

Payment methods

  • American Express
  • Diners Club
  • Discover
  • Meta Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

TDK LAMBDA SWS-100-5 Switching Power Supply
TDK LAMBDA

TDK LAMBDA SWS-100-5 Switching Power Supply Output 5Volts, 20Amps

$197.00

TDK LAMBDA SWS-100-5

Features

-Low Cost

-Power Factor Correction to EN61000-3-2

-Universal Input (85 - 265VAC)

-Input Transient Protected IEC61000-4

-Enclosed

-Global safety Approvals

-Level B EMI

Key market segments and applications:   industrial, comm, Led, test.

Specifications:

  • Input Voltage range (1): 85 - 265VAC (47 - 63Hz) or 120 - 370VDC
  • Inrush Current (115 / 230VAC): 16/32
  • Power Factor: Meets EN61000-3-2
  • Input Current (100/200VAC): 1.2/0.6 
  • Temperature Coefficient: <0.02%/°C  
  • Total regulation: <5%
  • Overcurrent Protection: >105%, Constant Current Style
  • Overvoltage Protection: 115 -135%, Cycle AC line to reset
  • Hold Up Time (Typ): 20ms at 115VAC
  • Leakage Current (max): 0.75mA (0.5mA typ@230VAC)
  • Remote Sense:  Not Available
  • LED Indicator: Green LED = On
  • Operating Temperature:  -10 to +70°C (See table for derating - model specific)
  • Storage Temperature:  -30 to +85°C
  • Operating Humidity: 30 - 90% RH
  • Storage Humidity : 10 - 95% RH
  • Cooling: Convection
  • Withstand Voltage : Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
  • Isolation Resistance: >100M at 25°C & 70%RH, Output to Ground 500VDC
  • Vibration (non-operating): 19.6m/s2 (10 - 55Hz (constant sweep 1 min) X, Y, Z for 1 hour)
  • shock: < 196.1 m/s2 (20G)
  • Safety Agency Approvals:  UL60950-1, CSA60950-1, EN60950-1, CE Mark, EN50178
  • Conducted & Radiated EMI: EN55011 / EN55022-B, FCC Class B, VCCI-B
  • Recommended EMI Filter: RSEL-2002W
  • Immunity :   EN61000-4-2,-3,-4,-5,-6,-8,-11
  • Weight (Typ): 600g
  • Size (WxHxD): 3.78 x 1.77 x 7.4 in

Model selector:

-voltage:              5V

-Adjust range:   4.5-5.5V

-Max Curr. (A):    20

-Load Reg (mv):  40

-Line Reg (mv):   20

-Ripple noise:    100

-Eff (3) (typ) %:   75/77

Derating:

At 25°C: 100 %

At 30°C:  100 %

At 35 °C:  100 %

At 40°C:  100 %

At 45 °C: 100 %

At 50 °C: 87%

At 55 °C: 73 %

At 60 °C: 60 %

View product